Welcome to logikeditor.de
With the LOGIKEDITOR, we offer you user-friendly, web-based software that is already available in the EIBPORT and LOGIKMODULE is integrated. Create circuits and sequences easily and intuitively to make your building automation more efficient and flexible.
On this platform, you have access to a wide selection of ready-made logic groups for different automation areas, provided by both BAB TECHNOLOGIE and the community. In this way, you can tailor your building automation even better to your needs.

Photovoltaic surplus - Constant charging

PV surplus for use of charging batteries (e.g. motor vehicle); charging takes place with constant power according to own specifications (settings). Input values (user settings): - Input default power...
EP, LOM
802

Solax Inverter Query

This logic group is used to cyclically query the current status of a Solax inverter. The http request in this logic group queries the current status from the Solax Cloud. The...
EP, LOM
450

Solar surplus for hot water boiler (dim)

With this logic group, the solar surplus is used for hot water preparation. About the function. A percentage value for the dimmer control of the heating rod is calculated from the "current supply/supply" input....
EP, LOM
578

Balcony PV - surplus energy

Balcony PV surplus energy control to avoid backfeeding The domestic energy base load of a household is usually less than a balcony PV system generates. This raises the question: Where to put the surplus?...
EP, LOM
504

PV forecast.solar

The http request in this logic group uses the free but limited API access of "forecast.solar" for the solar forecast. Thus, the expected yield for today and tomorrow can be...
EP, LOM
1,321

Solar surplus for water heater *

With this logic group, the solar surplus of a PV system can be used with the help of a heating cartridge in the hot water boiler (built-in heating cartridge with 3 identical heating rods), e.g. to heat gas or oil....
EP
693

SolarEdge value query

This example shows how to read values from a SolarEdge solar system. The SolarEdge Monitoring API is used to retrieve values from a SolarEdge solar system. To the function...
EP, LOM
996

Solar-Log 300

This logic group reads out current measured values of a photovoltaic system. The read-out data can thus be displayed in a KNX visualisation or made available for functions and actions. The measured values of the photovoltaic system...
EP, LOM
1,593

Photovoltaic Surplus - Dynamic Charging

In order to optimally use photovoltaic energy, it is necessary to use the energy surplus variably in times of high PV yield. Flexible energy storage systems, such as a car battery, help to...
EP, LOM
1,046

Kostal PIKO Solar

This logic group reads out current measured values of a photovoltaic system. The read-out data can thus be displayed in a KNX visualisation or made available for functions and actions. The measured values of the photovoltaic system/storage...
EP, LOM
1,475

Three inverters with message

This extended logic group enables the retrieval of measured values via HTTP request from a Fronius Symo 3-M inverter. The queried measured values are then sent to the KNX bus. In addition, a...
EP, LOM
1,360

BYD energy storage instantaneous values

Measured values from a BYD energy storage unit are interrogated cyclically with this logic group and sent to the KNX bus. The connection of a BYD energy storage unit in this project is via a...
EP, LOM
864
Filters
Reset