This logic group calculates the "felt temperature".
This value is only determined for temperatures below 10°C. Above 10°C, the "felt temperature" and the measured temperature do not differ.
The unit for wind speed is km/h!
Formula:
W = 13.12 + 0.6215 * T - 11.37 * V^0.16 + 0.3965 * T * V^0.16